Read out settings

After any error é1, é2, é7, é10 or é13 ; the 3
minute venting cycle will run first before starting the boiler.
• Checking CH function;
- Ensure the time control is in the CH on position
- Set the room thermostat on a high demanding temperature
and, the display shows
[1 ; pre-purge stage
[2 ; Ignition stage
[3 ; operating in CH mode.
- Set the room thermostat back to a lower temperature (no
more heat demand), the display shows;
[5 ; waiting-time; 3 to 10 minutes (only when flow tem-
perature has already been reached and heating demand is
still existing)
[1 ; pre-purge stage
[6 ; pump run on after CH or DHW is satisfied
[0 ; stand-by mode
2.10.6
Read out settings
The following settings can be read out in the 'user menu':
- t1 = flow temperature [°C];
- t2 = return temperature [°C];
- t3 = calorifier temperature [°C];
- t4 = outside temperature [°C];
- fl = ionisation current [uA];
- ñf = fan speed [rpm];
• Press the [+] key, until t1 appears and, for example, 68
(68°C), the current flow temperature;
• Press the [+] key again until t2 appears and, for example,
45 (45°C), the current return temperature;
• Press [+] key again until fl appears and e.g. ^0 (6uA),
the present ionisation current;
• Press [+] key again until ñf appears and e.g. 30 (3000
rpm), the present fan speed;
• Press [+] key again and the read-out cycle will start again
with t1, etc.;
• Press [reset] key to return to the display with the current
operating status.