Adjustment > Adjustment Procedure

6-4-9 Stabilizer

Note:
Perform STABILIZER only after replacing any component on the GYR circuit board or executing
"Data Initialize".
This item STABILIZER is not an adjustment, but is performed to write the camera shake correction
value contained in adjustment program to EEPROM.
Although the camera shake correction value written to EEPROM is an adjustment value inherent in
individual devices when shipped from the factory, the camera shake correction value contained in
adjustment program is an average value set at the factory. Therefore, after STABILIZER is
executed, the performance of stabilizer will deteriorate slightly.
Procedure:
1) Check STABILIZER on the ADJUST MENU screen.
2) Click the EXECUTE button on ADJUST MENU screen
to start writing of camera shake correction value.
3) When adjustment is complete, the ADJUSTMENT
FINISHED dialog will appear: Click the OK button in
dialog to restore the ADJUST MENU screen.
ADJUST MENU screen
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
MODEL NAME:
ADJUST MENU
PLEASE SELECT ADJUST
ADJUSTMENT FINISHED dialog
FINISHED
ADJUSTMENT FINISHED.
6 - 30
××××
DATA INITIALIZE
VIDEO LEVEL
BURST LEVEL
SAMPLING PULSE
AUTO FUCUS
AUTO IRIS CONTROL
MATRIX
CHROMA GAIN
1
STABILIZER
SPOT NOISE
LCD
EVF
2
EXECUTE
RETURN
3
OK