Adjustment Program; Data Creation Program - Hitachi DZ-MV350A Service Manual

Hide thumbs Also See for DZ-MV350A:
Table of Contents

Advertisement

Adjustment > Creating Reference Data
6-1-5 Storing or Deleting Adjustment Program
Information:
The adjustment program also includes a program for creating reference data.
(1) Storing
1) Start the PC.
2) Start Explorer and create a new folder in HDD of PC. The name "map03w" is recommended for
the folder: If a folder with the same name exists, give the folder a similar name that is easily
understandable.
Note:
Be sure to manage the adjustment programs for Windows and MS-DOS in different folders:
Managing them in the same folder will interfere with adjustment.
3) Copy all the folders and files on adjustment floppy disk to the map03w folder.
(2) Deleting
If it is necessary to delete the adjustment program from hard disk drive (HDD) of PC, delete the
map03w folder that was created during storage.
6-1-6 Starting and Terminating Reference Data Creation Program
The reference data creation program will not start unless the connections for creating reference data
are correct, and the DVD video camera/recorder or DSP-R jig is powered: Make sure that the
connections are correct, the power switch on DVD video camera/recorder is set to "VIDEO", and the
DC power supply for DSP-R jig is turned on.
For subsequent operation, operate the PC mouse while watching the PC monitor screen.
Information:
1) Display ×××× on subsequent PC screen shows the model name.
2) The numbers on PC screens show the operational procedure.
(1) Start
1) Start the PC. If the PC has already started, terminate all other applications.
2) Start Explorer, and double-click the "SETUPforMAP2003W.EXE" file in map03w folder to start
the program.
3) Once the program has started, the COMMUNICATION PORT SETTING screen will appear.