Toner Supply Motor /C, K (M7); Fusing Motor (M4) - Konica Minolta bizhub C30P Service Manual

Hide thumbs Also See for bizhub C30P:
Table of Contents

Advertisement

6. Other
6.3.27

Toner supply motor /C, K (M7)

1. Remove the PWB box /1.
See P.67
[3]
6.3.28

Fusing motor (M4)

1. Remove the PWB box /1.
See P.67
2. Remove the PWB box /2.
See P.68
[1]
70
[1]
[2]
A011F2C067DA
[2]
[3]
A011F2C068DA
Field Service Ver. 2.0 May 2007
2. Disconnect the connector [1], and
remove two screws [2] and the toner
supply motor /C, K [3].
NOTE
• When installing the toner supply
motor /C, K, try to insert it straight,
and take care not to damage the
gears.
3. Disconnect the connector [1], and
remove four screws [2] and the fus-
ing motor [3].
NOTE
• When installing the fusing motor,
try to insert it straight, and take
care not to damage the gears.

Hide quick links:

Advertisement

Table of Contents
loading