Malfunctions / Troubleshooting
8
Malfunctions / Troubleshooting
INFORMATION
Should you encounter problems while troubleshooting or if
you do not manage to completely eliminate a problem by
following the measures described here, please contact
your specialist dealer.
Malfunctions are indicated by the flashing „Battery Capaci-
ty" LED on the control panel. Table 5 describes the individu-
al indications with the corresponding sources of the problem
as well as the possible causes and measures to be taken.
If you do not manage to completely eliminate the problems with
the described measures, your specialist dealer may be able to
read the exact error code with the hand programming device
and undertake a more systematic analysis of the system.
All problems that have ever occurred are saved in a list and
can be retrieved, for example, in case of a general overhaul of
the power wheelchair. The saved data can be used to deter-
mine future service and maintenance intervals, for example.
122
Ottobock
|

8.1 Warning

A warning indicates a status or malfunction of one or sever-
al components of the power wheelchair. The function of
components that have no errors is not restricted.

8.2 Errors

CAUTION
Risk of injury if the power wheelchair stops abruptly. In
the event of communication problems in the bus system of
the controls, the system triggers an emergency stop to pre-
vent any uncontrolled functions. Depending on the respec-
tive malfunction, it is possible to drive the wheelchair out of
a danger zone by turning the control unit back on.
If the driving function is still not available after switching on
the controls again, the brakes must be released (see sec-
tion 6.4) to switch over to the pushing mode. After the po-
wer wheelchair has triggered an emergency stop, contact
a specialist dealer as soon as possible!
CAUTION
Risk of accident due to uncontrolled driving behaviour.
Uncontrolled movements can occur during the operation of
the power wheelchair as a result of malfunction. In this
case, please contact your authorised dealer immediately.
A200

Advertisement

Chapters

Table of Contents
loading

Table of Contents