16Dstu Digital Station Pcb (P/N 80021A); 8Astu 8 Port Analog Station Pcb (P/N 80041B) - NEC DS1000 Product Description

Hide thumbs Also See for DS1000:
Table of Contents

Advertisement

Make a note of the following...
G

16DSTU Digital Station PCB (P/N 80021A)

Each 16DSTU PCB connects 16 digital extensions (i.e., keysets). You can also
connect 2-OPX Modules. The 16DSTU has a Mode Switch (for taking the PCB
out of service). It also has a status LED that indicates proper PCB operation — as
well as a port activity LED that flashes faster as traffic on the PCB increases. You
can install up to 2 16DSTU PCBs in a 4-Slot Cabinet. You can install up to 6
16DSTU PCBs in an 8-Slot Cabinet. See DS2000 System Configuration on
page 22 for more.
Make a note of the following...
G
G
G
G

8ASTU 8 Port Analog Station PCB (P/N 80041B)

The 8ASTU PCB connects 8 analog extensions. These can include single line
telephones, fax machines, modems or Voice Mail ports. Just like the 16DSTU
PCB, the 8ASTU PCB has a Mode Switch (for taking the PCB out of service), a
status LED indicating proper PCB operation, and a port activity LED to indicate
traffic on the PCB. The number of 8ASTU PCBs you can install depends on sys-
tem configuration. Turn to DS2000 System Configuration on page 22 for more.
Make a note of the following...
G
G
G
DS1000/2000 Product Description
When connecting a music source, an External Paging system, or a device controlled by the
CPU relay, make sure the connected device is compatible with the CPU input and output spec-
ifications. Review your system's Hardware Manual for more.
CPU P/N 80025B at a glance —
Music Inputs . . . . . . . . . . . . . . . . . . . . . . . .1
Relay Contacts. . . . . . . . . . . . . . . . . . . . 1 set
When connecting 2-OPX Modules, always observe the System Load Factor.
See page 22 for more.
You must install a separate power supply for every 2 16DSTU PCBs installed.
In all systems, you must install a 16DSTU PCB in the first universal slot.
You can install 16DSTU PCBs in any universal slot.
16DSTU PCB P/N 80021A at a glance —
Digital Station Ports . . . . . . . . . . . . . . . . .16
The 8ASTU PCB provides high voltage message waiting for single line sets
with high voltage message waiting lamps.
The 8ASTU PCB also provides Caller ID to single line sets.
You can install 8ASTU PCBs in any universal slot except the first.
8ASTU PCB P/N 80041B at a glance —
Analog Station Ports . . . . . . . . . . . . . . . . . .8
Provides high voltage message waiting.
Section 2: Components
Page Outputs . . . . . . . . . . . . . . . . . . . . . . . 1
DTMF Receivers and Generators. . . . . Yes
Installs in any universal slot.
Installs in any universal slot but slot 1.
Also provides Caller ID to single line sets.
Section 2: Components N 11
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds2000

Table of Contents