Low-Battery Shut-Down - Windsor Flex 3 FLX3 Operating Instructions Manual

Table of Contents

Advertisement

LOW BATTERY SHUT-DOWN
The electronic system is equipped with battery
voltage sensors. When the batteries are exhausted
to a preset level, the scrubbing system will shut
down to protect the batteries from damage, and the
battery lockout icon will appear on the display.
TO REMOVE BATTERIES
1. Stop the machine in a clean area next to the
charger.
2. Turn off machine and set parking brake.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, apply parking
brake, turn off machine and remove key.
3. Drain recovery tank.
4. Raise the tank and raise the support arm to lock
in place.
5. Disconnect battery pack from the machine.
6. Use the proper size open end wrench to
disconnect main ground wire first and secure
cable terminal away from batteries.
7. Disconnect main positive lead and secure cable
terminal away from battery/batteries.
8. Loosen both terminals on each jumper cable
and remove one at a time.
9. Prepare a suitable battery site to place batteries.
10. Attach suitable battery lifting device and lift
batteries from the machine.
!
CAUTION
Batteries are a potential environmental hazard.
Consult your battery supplier for safe disposal
methods.
TO REPLACE BATTERIES
1. Refer to diagram. Place batteries in battery
compartment.
2. Connect all jumper cables positive to negative to
the six batteries.
3. Connect the positive cable to battery in the
position shown.
4. Connect negative cable to battery in the position
shown.
FLX3 980087 04/01/03
MAINTENANCE
_
_
BLK
BLK
RED
RED
RED
RED
_ BLK
_
BLK
+
RED
_
BLK
RED
_
BLK
4-4