CONTROLS
Icon appears if throttle is depressed when the key is turned on. To correct, lift foot off of throttle. If this
does not clear the icon, the throttle may be damaged and should be checked by a qualified service
technician.
The float switch is located inside the recovery tank. The purpose of the float switch is to notify the user
that the recovery tank is full. When the float switch is activated, the scrub brush motors and solution flow
will stop, the scrub deck will raise, the squeegee will rise after 60 seconds, and the vacuum motor will
turn off 10 seconds later.
The battery meter can be viewed at the left side of either information screen 1 or information screen 2.
The level of battery charge is indicated by the horizontal bars in the battery meter box. When the
batteries require charging, the icon will flash and a battery inhibit icon will appear on the right side of
either information screen. Scrub and solution functions that are running when the battery inhibit icon
appears will be automatically shut off. It is not possible to restart scrub functions while the battery inhibit
is displayed. The controller reserves enough battery charge to allow pick-up of residual water and
transport back to a charging station.