Detaching And Refitting The Drum Separation Claws - Kyocera KM-1620 Service Manual

Hide thumbs Also See for KM-1620:
Table of Contents

Advertisement

2C9

(2) Detaching and refitting the drum separation claws

Follow the procedure below to replace the drum separation claws.
Procedure
1. Remove the drum unit (see page 1-6-33).
2. Push the drum separation claws with the
minus driver from the top of the corner hole
and remove the claws.
3. Replace the drum separation claws and refit
all the removed parts.
1-6-34
Drum separation claws
Drum
separation
claw
Drum unit
Coner hole
Figure 1-6-63