Kyocera KM-1620 Service Manual page 102

Hide thumbs Also See for KM-1620:
Table of Contents

Advertisement

2C9-2
Code
C0420
Optional first paper feeder communi-
(A0420*)
cation problem
• Communication fails five times suc-
cessively.
C0500
Optional second paper feeder com-
(A0500*)
munication problem
• Communication fails five times suc-
cessively.
C0510
Optional third paper feeder commu-
(A0510*)
nication problem
• Communication fails five times suc-
cessively.
C0610
Bitmap (DIMM) problem
(A0610*)
• There is a problem with the data or
address bus of the bitmap DRAM.
C0620
Memory input interface problem
(A0620*)
• Reading-in of an image does not
complete within 10 s of the start of
image transmission.
C0630
DMA problem
(A0630*)
• DMA transmission of compressed,
decompressed, rotated, relocated or
blanked-out image data does not
complete within the specified period
of time.
C0800
Image processing problem
(A0800*)
• JAM05 is detected twice.
C2000
Drive motor problem
• LOCK ALM signal remains high for 1
s, 1 s after the drive motor has turned
on.
"A" is displayed on the operation panel.
1-5-16
Contents
Causes
Check procedures/corrective measures
Paper feeder in-
Check the installation state of the paper
stalled incorrectly.
feeder and adjust it if it is not properly in-
stalled.
Defective main
Replace the main PCB or drawer main
PCB or drawer
PCB and check for correct operation.
main PCB.
Paper feeder in-
Check the installation state of the paper
stalled incorrectly.
feeder and adjust it if it is not properly in-
stalled.
Defective main
Replace the main PCB or drawer main
PCB or drawer
PCB and check for correct operation.
main PCB.
Paper feeder in-
Check the installation state of the paper
stalled incorrectly.
feeder and adjust it if it is not properly in-
stalled.
Defective main
Replace the main PCB or drawer main
PCB or drawer
PCB and check for correct operation.
main PCB.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
DIMM installed
Check if the DIMM is inserted into the
incorrectly.
socket on the main PCB correctly.
Defective DIMM.
Replace the DIMM and check for correct
operation.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Defective engine
Replace the engine PCB and check for
PCB.
correct operation.
Poor contact in
Reinsert the connector. Also check for con-
the main motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective drive
Replace the drive motor.
motor rotation
control circuit.
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushings and
tem.
gears. Check for broken gears and replace
if any.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2020

Table of Contents