(2) Detaching and refitting the DP separation pulley
Follow the procedure below to replace the DP separation pulley.
Procedure
1. Open the DP top cover.
2. Open the upper shift guide.
3. Remove two screws and then remove the
lower original feed guide.
4. Remove the stop ring and then DP separa-
tion pulley and torque limiter.
5. Check or replace the DP separation pulley
and refit all the removed parts.
DP top cover
Screw
Lower original
feed guide
Figure 1-5-7
Torque limiter
DP separation
pulley
Figure 1-5-8
3LL/3LK
Upper shift guide
Screw
Stop ring
1-5-5