Kyocera KM-1620 Service Manual page 198

Hide thumbs Also See for KM-1620:
Table of Contents

Advertisement

2C9
Connector Pin No.
YC13
1
2
Connected
3
to the key
4
counter
YC14
1
2
Connected
3
to the exit
4
motor
YC15
1
2
Connect to
3
the exit
4
switch and
feedshift
switch
YC16
1
2
Connected
3
to the
4
scanner
motor
YC17
1
2
Connected
3
to the
4
inverter
5
PCB
6
YC18
1
2
Connected
3
to the
4
original
5
detection
6
switch and
scanner
home
position
switch
YC19
1
2
Connected
3
to the
original size
detection
sensor
YC20
1
2
Connected
3
to the
4
power
source PCB
YC21
1
2
Connected
3
to the
4
power
5
source PCB
6
7
8
2-3-12
Signal
I/O
+24 V1
O
KEYCN
O
S.GND
-
KEYENBN
I
COMDA
O
COMDNB
O
COMDNA
O
COMDB
O
P.GND
-
EXTSMN
I
SEPSWN
I
+5 V2
O
ISMDA
O
ISMDNB
O
ISMDNA
O
ISMDB
O
LAMPN
O
P.GND
-
+24 V1
O
+24 V1
O
P.GND
-
LAMPN
O
+5 V2
O
HPSWN
I
S.GND
-
+5 V2
O
OPSWN
I
S.GND
-
+5 V2
O
ORGLSWN
I
S.GND
-
+5 V
I
S.GND
-
P.GND
-
+24 V2
I
+24 V
I
+24 V1
I
+24 V1
I
P.GND
-
P.GND
-
COUNTN
-
MHEATN
O
SHEATN
O
24 V DC power supply for key counter
Key counter count signal
Ground
Key counter set signal
EM control signal (A)
EM control signal (_B)
EM control signal (_A)
EM control signal (B)
Ground
ESW on/off
FSSW on/off
5 V DC power supply for ESW/FSSW
SM control signal (A)
SM control signal (_B)
SM control signal (_A)
SM control signal (B)
EL on/off
Ground
24 V DC power supply for inverter PCB
24 V DC power supply for inverter PCB
Ground
EL on/off
5 V DC power supply for SHPSW
SHPSW on/off
Ground
5 V DC power supply for ODSW
ODSW on/off
Ground
5 V DC power supply for OSDS
OSDS on/off
Ground
5 V DC power supply from PSPCB
Ground
Ground
24 V DC power supply from PSPCB
24 V DC power supply from PSPCB
24 V DC power supply from PSPCB
24 V DC power supply from PSPCB
Ground
Ground
Not used
FH-M on/off
FH-S on/off
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2020

Table of Contents