(4) Detaching and refitting the heat roller separation claws

Follow the procedure below to replace the heat roller separation claws.
Procedure
1. Remove the fixing unit and separate the fixing
right unit and left unit (see page 1-6-38, 39).
2. Detach the fitting portions and then remove
the heat roller guide from the fixing left unit.
3. Remove the heat roller separation claws from
the fixing left unit.
4. Replace the heat roller separation claws and
refit all the removed parts.
Heat roller guide
Figure 1-6-75
Heat roller separation claws
Fixing left unit
Fixing left unit
Figure 1-6-76
2C9
1-6-41