1-6-4 Drum section

(1) Detaching and refitting the drum unit

Follow the procedure below to replace the drum unit.
Cautions:
• Avoid direct sunlight or strong light when detaching and refitting the drum unit.
• Never touch the drum surface when holding the drum unit.
Procedure
1. Open the front cover and left cover. Remove
the waste toner box and toner container.
2. Remove the inner cover.
3. Remove the screw holding the developing
release lever.
4. Pull the developing release lever and then
release the developing unit.
5. Remove the screw and detach the connector
and then remove the drum unit from copier.
6. Replace the drum unit and refit all the
removed parts.
Inner cover
Developing release lever
Figure 1-6-61
Drum unit
Figure 1-6-62
2C9
Connector
1-6-33