(1) Original scanning
The original image is illuminated by the exposure lamp (EL) and scanned by the CCD PCB (CCDPCB) in the image
scanning unit via the three mirrors, the reflected light being converted to an electrical signal.
The scanner and mirror frames travel to scan on the optical rails on the front and rear of the machine to scan from side to
side. The speed of the mirror frames is half the speed of the scanner. When the DP is used, the scanner and mirror
frames stop at the DP original scanning position to start scanning.
CCDPCB
MPCB
YC7-1-
YC7-7
YC1-1-
YC1-7
YC2-2
PDPCB
Original
EL
YC8-1-
YC8-18
YC6-1-
YC6-22
APCPCB
PM
PM
LSU
Figure 2-1-4 Optional section block diagram
YC2-1
INPCB
YC2-3
YC1-1,6
YC17-1,6
YC16
-1,2,3,4
YC1-1-
YC1-22
EPCB
YC3-3
SM
OSDS
YC19-2
OSDS
ODSW
YC18-5
ODSW
SHPSW
YC18-2
SHPSW
2C9