LifeSpan Chief Owner's Manual page 19

Table of Contents

Advertisement

Pa circuit board bolt
PA circuit
lock well or not put well the
board
connector.
SENSOR
well.
No hand
pulse
The hand pulse
touch well
Message failure
E01
E02
burst clash
E03
No sensor signal
E04
Incline study failure
E05
Over loading protector
CHIEF
3.
is touched well.
Take
does
not
cover and press PA circuit
board to see if it is short
circuit or loosen.
1check if
circuit or lossen.
does
not touch
2.
check
computer
tie-in is connected well.
3.Put the both hands to
does
not
bedew a litter or scrub with
both hands.
1.the connected wire is
wrong.
2.Power supply voltage
shortage
1.Power tube badness
2.Drivers badness
3.Motor failure
1.Sensor wire badness
2. It is no use for the motor
magnetic.
3.Drivers badness
1.Study failure
2. Incline motor badness
3.Drivers badness
4.Incline motor wire
not connect well
1.The limited weight
2.Drivers badness
check
the wire tie-in if it
away
the bottom
the wire is short
the wire and
to see
if the
does
- 19 -
3.Reset to insert the wire tie-in.
Reset to put the connector and
lock the bolt.
1.Change the wire or reset.
2.Reset to insert the wire
3.Reset to test.
1.Use the multimeter to test the
wire is stand or fall.
2.To
test if
the outside and
inside voltage is normal.
(DC12V)
3.SCM is badness.
1.Change the power tube
2.Change the drivers
3.Change the motor
1.Change the sensor wire
2.Change the magnetic or
reset the magnetic
3.Change the drivers
1.To reset study
2.Change the incline motor
3.Change 24C02 or change
the drivers
4.Insert the incline motor wire.
1.Do not exceed the treadmill
user's weight.
2.Change the limit resistance
or change the drivers