Advertisement

Control Panel Setup
Overall Control Panel
Settings
In panel setup, you carry out settings particular to the
control panel.
Interchanging the Bank Order or
Disabling Operation
You can set the assignments for the M/E and PGM/PST
banks, and then enable, disable, or inhibit operations for
each of the M/E and PGM/PST banks.
1
In the Engineering Setup >Panel >Config menu
(7321), select the Bank you want to set.
The Bank selection here indicates the physical position
on the control panel.
Corresponds to the 2nd row and 3rd row from the top;
the 1st row cannot be used.
2
Select the bank that you want to assign to the selected
Bank number in the <M/E Assign> group.
The status area shows the interchanged state of the
banks.
Notes
It is not possible to assign the same M/E logical bank
to more than one physical bank. Be sure to make
different M/E assignments.
3
For the selected Bank number, in the <M/E
Operation> group, select one of the following.
Enable: Enables panel display and operation of the
bank.
Disable: Enables only panel display, and disables
operation of the bank.
Inhibit: Disables both the panel display and operation
of the bank.
Chapter
Notes
When this is set to Inhibit, snapshots of the bank are
not recalled.
Linking Switcher Bus and Router
Destination
To provide links between the switcher bus and router
destination, make the following settings as required.
Matrix selection: Selects the target of link setting from
the eight matrices (1 to 8).
Matrix position definition: Sets the start address and
level for the source and destination on the S-Bus.
Link table setting: Links a switcher cross-point button
and matrix source.
Link bus setting: Links a switcher bus address and router
destination.
Selecting a matrix number
1
Open the Engineering Setup >Panel >Config
>External Bus Link menu (7321.3).
2
Set the following parameters.
No.
Parameter
Adjustment
1
Link No
Link number
2
Link Matrix
Matrix number
3
Press [Link Matrix Set].
To delete a link
With the link selected, press [Clear].
Defining the position of a matrix
Specify where in the 1024 × 1024 S-Bus space the link
matrix is to be provided, by setting the source and
destination start address.
For the matrix selected in the External Bus Link menu, use
the following procedure.
17

Overall Control Panel Settings

219