Selecting Cross-Point Assign Tables

You can select the cross-point assign table to be used for
the M/E-1 or PGM/PST bank.
Notes
It is not possible to assign cross-point tables 5 to 14 to a bus
of a switcher operated by an MKS-8080/8082 AUX Bus
Remote Panel.
1
In the Engineering Setup >Panel >Xpt Assign menu
(7322), select the bank or bus.
2
Select a table.
3
Press [Table Assign Set].
Exporting Source Names and
Destination Names
To send the source names and destination names to the S-
Bus, use the following procedure.
1
Open the Engineering Setup >Panel >XPT Assign
>Name Export menu (7322.9).
2
Set the destination station ID.
No.
Parameter
1
Station ID
a) If set to 255, the information is sent to all stations (with display of
"All").
3
Press [Src Name Export].
This exports the source names to the station selected in
step 2.
4
Press [Dest Name Export].
This exports the destination names to the station
selected in step 2.
Notes
Since destination names cannot be selected freely,
fixed names are used.
226

Router Remote Control Settings

Adjustment
a)
Station ID setting
Assigning a Cross-Point Button to
Enable/Disable Side Flags
By assigning the side flag function to the rightmost button
in a cross-point button row, you can use this button to
enable/disable side flags for each of the M/E and PGM/
PST banks.
This setting applies to all of the M/E and PGM/PST banks.
When you make this assignment, the SHIFT button (the
button assigned to the shift function) is moved one to the
left.
Notes
If a macro attachment is set, when you assign the button to
the side flag function, the button numbers are offset, and
therefore when you press the button this does not execute
the macro. The settings, however, are maintained, so that
when you cancel the side flag assignment, the macro can
be accessed once more.
For details about side flag operation,
Settings" (p.
128).
1
Open the Engineering Setup >Panel >Xpt Assign
>Side Flags Button Assign menu (7322.10).
2
Press [Side Flags Btn Assign], turning it on.
Router Remote Control
Settings
Assigning a Destination to a
Destination Selection Button
1
Open the Engineering Setup >Panel >Router Remote
>RTR Mode Setting menu (7323.1).
2
Select a destination selection button and the
destination to be assigned to the button.
Notes
When a destination selection button having a number
in the range 65 to 128 is selected, source table
selection automatically becomes invalid, and therefore
the Inhibit function also becomes invalid.
3
Press [Dest Set] to confirm the selection.
4
If in step 2 you selected a value in the range 1 to 64,
select the source table.
1 "Side Flag