Note: The following Simpson Duravent kits are
recommended for use with this appliance.
High-Wind
(Bristol 46DVA-CL33)
(Bedford 46DVA-CL34)
Prairie Co-Linear Kit
(Bristol 46DVA-CL33P)
(Bedford 46DVA-CL34P)
Only certified venting systems or components
may be installed with this fireplace.
1.
Measure chimney height, cut ex liner (min.10') as
required. Mark one pipe at both ends to identify
combustion air intake pipe from ue outlet pipe.
2. Attach marked ex liner pipe to the intake side
of vent terminal. Seal and secure with sealant and
screws provided. Attach the other pipe to the outlet
side of vent terminal. Seal and secure with sealant
and screws provided.
3. Insert both ex liners from top of the chimney, down
through the damper opening.
4. Before attaching vent terminal to top of chimney,
apply a bead of caulking to top of clay liner. Slip
vent terminal over liner and secure in place with lat-
eral retaining bolts.
5. For larger chimneys, an optional ashing is available
which may be cut and tted to suit. The ashing
attaches to the underside of the terminal with four
nuts provided. Caulk the ashing in place to seal any
gaps.
Figure 24: Flue Adaptor Plate Conections.
5055.633-B

Venting

Figure 25:
High wind vent
terminal.
Intake
Air
Figure 26: Co-linear venting.
18
NOTE:
Bedford has a 4 inch dia.
exhaust vent and a 3 inch
intake vent.
Bristol has both 3 inch dia.
exhaust and intake vents.
**NOTE**
Exhaust
Intake Damper Position
Air
adjustment may vary
depending on particular
installation
Max Vent Height
50' (15.25m)
25'-50'
3/4" Open
16'-25'
1" Open
10'-16'
Full Open
Min. Vent Height
10' (3m)
050216-44