Maintenance; Glass Door; Annual Inspection; Periodically - Pacific energy BRISTOL Installation And Operating Instructions Manual

Table of Contents

Advertisement

CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for
unit to cool before servicing appliance. It is recommended that the replace and
its venting should be inspected at least once a year by a quali ed service person.

Glass Door:

Warning: Do not operate replace with glass panel removed, cracked or broken.
Replacement of the glass panel should be done by a licensed or quali ed service
person.
Do not strike or otherwise impact the glass in anyway that may cause it to break.
If the glass becomes cracked or broken it must be replaced before using the
replace. Replacement glass can be obtained from your nearest Town & Country
Fireplaces
dealer. The size required is 52" x 16" x 5mm. Use ceramic glass only.
TM
Do not substitute with any other type.
To remove broken glass, remove window frame as noted in See "Door Installation/
Removal" on page 23.
Unclip the Glass Retainer Clips located at the top and sides of the Window
Frame. Pull the top edge of the glass out of the frame rst, then lift it up and out
of the bottom edge.
Install the new piece of glass with the gasket into the frame so that the thicker bead of gasket faces the replace.
Re-install glass retaining clips.

Annual Inspection:

a) Remove glass panel and pebble assemblies. Inspect pebble and burner assemblies for soot buildup. If excessive
buildup of soot is present, have a quali ed service person inspect and adjust unit for proper combustion. Clean logs
and burner with a brush or vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper ame size and operation. Clean pilot free of soot, dust or any other deposits (See
Figure 18).
c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled
for cleaning, it must be properly assembled and re-sealed. Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline and other ammable
vapours and liquids.

Periodically:

a) Viewing glass may be cleaned as necessary with replace glass cleaner.
b) Exterior nish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the replace.
Do not clean glass when hot.
BRSL.BODYB
050216-44
BDFD.BODYB

Maintenance

13
PILOT
FLAME SENSOR
PILOT FLAME
Figure 18: Pilot assembly.
5055.633-B
ELECTRODE