Sensor (Stapler Pass Through) Lingering Jam Service Check - Lexmark X651de Service Manual

Hide thumbs Also See for X651de:
Table of Contents

Advertisement

Sensor (stapler pass through) lingering jam service check

Step
1
Check the output option for proper installation.
Is the above component properly installed?
2
Check for obstructions in the media path between the
Sensor (stapler pass through) machine and the media bin.
Is the media path free from obstructions?
3
Check the sensor (stapler pass through) for proper
operation.
1. Enter the diagnostic mode
2. Select Finisher sensor test
3. Select Sensor test
4. Select pass & media
5. Observe the line item "passthru"
Does the display on the operator panel, change every time
the sensing area of the above sensor is interrupted or
blocked.
4
Check the above sensor for proper connection.
Is the above sensor connected properly?
Sensor (stapler pass through) static jam service check
Step
1
Check the media path for partially fed or jammed media.
Is the media path free from partially fed or jammed media?
2
Check the sensor (stapler pass through) for proper
operation.
1. Enter the diagnostic mode
2. Select Finisher sensor test
3. Select Sensor test
4. Select pass & media
5. Observe the line item "passthru"
Does the display on the operator panel, change every time
the sensing area of the above sensor is interrupted or
blocked.
3
Check the above sensor for proper connection.
Is the above sensor connected properly?
Check
Check
Yes
Go to step 2.
Remove then
reinstall the output
option
Go to step 3.
Remove
obstructions.
Go to step 5.
Go to step 4.
Replace the output
Replace the
option.
connection.
Yes
Go to step 2.
Remove any pre-
staged or jammed
media.
Go to step 4.
Go to step 3.
Replace the output
Replace the
option.
connection.