1.4

SHELF POSITION

The fire may be fitted below a combustible shelf providing there is a minimum dis-
tance of 200mm above the top of the fire and the shelf does not project more than
150mm. If the shelf overhangs more than 150mm the distance between the fire
and the shelf must be increased by 15mm for every 25mm of additional overhang
over 150mm.
1.5

HEARTHS

This appliance does not require the fitting of a hearth, but we do recommend that
a hearth of minimum width 760mm and minimum projection forwards of 125mm is
used. This recommended hearth can be manufactured from combustible or non-
combustible material.
2.1

UNPACKING THE FIRE

Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the the pack. Check the contents as listed :-
IMPORTANT :
DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE
GLASS PANEL IS BROKEN OR NOT SECURELY FIXED TO THE FIREBOX.
Packing Check List
1off
Fire box & foam seal / burner assembly
1off
Trim & magnets
1off
Fret, Ashpan & Mounting Brackets / Screws (Boxed)
1off
Boxed ceramic one piece fuel bed
1off
Flue Terminal unit
1off
Loose Items pack – containing:-
INSTALLATION OF FIRE
THE CARDBOARD FITMENT THAT IS AT THE TOP OF THE
CONVECTION APERTURE SHOULD NOT BE REMOVED
UNTIL THE APPLIANCE IS FULLY INSTALLED AND READY
TO BE LIT.
SECTION 2
Cable fixing kit, Section of Foil Tape
10 off rawplugs, 12 off No.8 x 10mm
screws
1 off 6mm Allen Key
1 off Right Hand Supply Pipe
10 off No.12 x 40mm fixing screws
1 off heat deflector
6