MK-212 SAW
RE-CIRCULATION
NOTE: When using the re-circulation method, the water should be changed often for longer pump life.
(A)
Press the free end of the
Cooling Transfer Tube onto
the Blade Guard Cooling Port
(D)
Place the Water Pump in the
back of the Water Basin
MK-212 ELECTRICAL CORD SETUP
CAUTION
Connect the Water Pump to
Fill the Water Basin until
water completely covers the
Water Pump suction
1. Before connecting the MK-212 to a power supply, be sure the voltage, cycle and
phase meet the requirements of TABLE 3 below.
VOLTAGE:
CYCLE:
PHASE:
2. If using an extension cord, make sure the length and wire gauge correspond to the
requirements listed in TABLE 1 on page 11. An extension cord that is too small in
wire gauge (diameter), or too long in length, will cause the motor to overheat and
could cause premature failure.
3. Use an approved Ground Fault Circuit Interrupter (GFCI)
4. Do not cover the motor vents as this could lead to motor overheating.
(B)
the MK-212
(E)
115v
60hz
1-phase Single Phase
Table 3
21
(C)
Ensure the Drain Plug is
installed in the Water Basin