Edid - IDK MSD-501 Command Reference Manual

Digital multi switcher
Hide thumbs Also See for MSD-501:
Table of Contents

Advertisement

MSD-501/502 Command Guide

3.3.10 EDID

@GED / @SED
EDID data
Function
Getting
Format
@GED
Return value
@GED, edid_1, edid_2, edid_3
Parameter
edid_1-5: EDID data
ch_1-3: Input channel
Example
@GED
@GED,0,0,3
@SED,2,3
@SED,2,3
Remarks
Those commands are only for digital input.
In order to use a copied data, read EDID data from the sink device in "@RME
Copying EDID (P.65)" in advance.
60
0 = Built-in EDID [Default],
1 = OUT1A MONITOR,
2 = OUT1B MONITOR,
3 = OUT2A MONITOR,
4 = OUT2B MONITOR,
101 to 108 = COPY DATA 1 to COPY DATA 8
0 = All digital inputs, 1 = IN1 to 3 = IN3
Setting
@SED, ch_1, edid_1 (, ch_2, edid_2・・・)
@SED, ch_1, edid_1 (, ch_2, edid_2・・・)
Getting EDID data.
IN3: EDID of the sink device connected to OUT2A.
Other inputs: built-in EDID
Setting IN2: EDID read from the sink device
connected to OUT2A.
Completed normally.