Fitting The Anchor Rods; Installing The Feed Pipe And Connecting Block - Buderus Logano G215 WS Installation And Maintenance Instructions Manual

Oil and gas-fired special
Hide thumbs Also See for Logano G215 WS:
Table of Contents

Advertisement

7.1.8 Fitting the anchor rods

USER NOTE
Insert the anchor rod before removing
the compression tool.
Never remove the compression tool
first.
SYSTEM DAMAGE
through incorrect spring washer assembly.
Ensure that the spring washers are
CAUTION!
arranged opposite each other on the
anchor rods.
Insert the anchor rods with spring washers into the
cast lugs on the left-hand and right-hand side as well
as adjacent to the lower boiler hubs.
Tighten the nuts on the anchor rod threads by hand.
Tighten the nuts 1 to 1½ turns on the anchor rods.
Release and remove the compression tool.

7.1.9 Installing the feed pipe and connecting block

The feed pipe, the connecting block and the sensor well
are already assembled if the boiler block is supplied as
a ready assembled unit.
USER NOTE
If there is insufficient space behind the
boiler, first push the feed pipe from the
front of the boiler into the boiler before
installing the connecting block (don't
forget the boiler hub flat gasket).
Secure the feed pipe to the connecting block using
×
M 8
16 screw and the flat gasket.
Logano G215 WS - We reserve the right to make any changes due to technical modifications.
Assembling the boiler block
1
5
Fig. 17 Fitting the anchor rods –arrangement of the spring
washers
1 Anchor rods
2 Nut
3 Spring washers
4 Cast lugs
5 Compression tool
A Spring washer arrangement
4
3
Fig. 18 Installing the feed pipe to the connecting block
1 Connecting block
2 Flat gasket
3 Feed pipe
4 M 8 × 16 bolts (brass)
7
2 3
4
A
1
2
1
23

Hide quick links:

Advertisement

Table of Contents
loading