7.1.11 Positioning the flue outlet

For this purpose, the flue outlet is equipped with packing
cord.
Remove the washers and nuts from the threaded
studs.
Position the flue outlet onto both threaded studs on
the rear section and secure using nuts.

7.1.12 Closing the boiler hubs

You will need the reducer, which is part of the standard
delivery, to fit the on-site fill & drain valve (fill & drain
valve).
Seal the reducer into the lower boiler hub at the rear
of the boiler.
Fit the boiler fill & drain valve to the reducer.
Close the upper boiler hub on the front section using
the dummy flange.
Insert the plug, together with its flat gasket, into the
lower boiler hub.
Logano G215 WS - We reserve the right to make any changes due to technical modifications.
Assembling the boiler block
Fig. 23 Installing the flue outlet
Fig. 24 Sealing in the reducer
1 Reducer (R 1½" to Rp ½")
1
Fig. 25 Closing the boiler hubs on the front section
1 Dummy flange
2 Plug
7