Shutting Down The Heating System; Standard Shutdown; Emergency Measures - Buderus Logano G215 WS Installation And Maintenance Instructions Manual

Oil and gas-fired special
Hide thumbs Also See for Logano G215 WS:
Table of Contents

Advertisement

10 Shutting down the heating system

10.1 Standard shutdown

Switch the control device ON/OFF switch to the OFF
(position "0"). This switches the boiler and all its
components OFF (for example the burner).
Close the main fuel shut-off valve.
SYSTEM DAMAGE
through frost.
The heating system can freeze up in cold
CAUTION!
weather if it has been switched off.
Leave the heating system switched ON
for as long as possible.
Protect your heating system against
freezing by draining the heating system
and DHW pipework at the lowest
possible point.

10.2 Emergency measures

Explain to your customer the measures required in
emergencies, for example during a fire:
Close the main fuel shut-off valve.
Isolate the heating system from the mains power
supply using the heating system emergency stop
switch or the corresponding domestic fuse.
Logano G215 WS - We reserve the right to make any changes due to technical modifications.
Shutting down the heating system
Fig. 70 Shutting down the heating system (Logamatic 2000)
1 ON/OFF switch
Fig. 71 Shutting down the heating system (Logamatic 4000)
1 ON/OFF switch
10
I 0
1
1
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents