WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
4.6 Removing the Sensors
4.6.1 CR Encoder
1.
Remove the Carriage Shaft / Carriage Unit. (p.88)
2.
Remove the two C.B.P. M2.6 x 5 screws that secure the CR Encoder Sensor
Board.
3.
Disconnect the PW Sensor FFC from the connector on the CR Encoder Sensor
Board, and remove the CR Encoder Sensor Board.
13) C.B.P. M2.6x5
CR Encoder
Sensor Board
Figure 4-156. Removing the CR Encoder Sensor Board
Disassembly And Assembly
(2±0.5 kgf.cm)
PW Sensor FFC
Connector
4.6.2 PF Encoder
1.
Remove the Upper Housing / Printer Cover. (p.72)
2.
Disconnect the FFC from the PF Encoder Sensor Board.
3.
Remove the C.B.S. M3 x 8 screw that secures the PF Encoder Sensor Holder.
Connector
Figure 4-157. Removing the FFC and the Screw that Secures
Removing the Sensors
PF Encoder Sensor Holder
FFC
the PF Encoder Sensor Holder
Revision C
5) C.B.S. M3x8
(6±1 kgf.cm)
124