WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
25. Disconnect the Sensor FFC from the connector on the CR Encoder Board, pull out
the Sensor FFC from the Carriage Unit, and remove the Carriage Unit.
Figure 4-81. Removing the Carriage Unit
After replacing or removing the Carriage Shaft and Carriage Unit,
A D J U S T M E N T
R E Q U I R E D
always make the required adjustments referring to the following.
 "Chapter 5
Adjustment
After replacing or removing the Carriage Shaft and Carriage Unit,
A D J U S T M E N T
R E Q U I R E D
be sure to perform the required lubrication referring to below.
 "Chapter 6
Maintenance
Disassembly And Assembly
CR Encoder Board
Sensor FFC
(p.128)"
(p.152)"
Disassembling the Printer Mechanism

4.4.6 ASF Assy

1.
Remove the Upper Housing Support Assy. (p.74)
2.
Remove the C.B.S. M3 x 8 screw that secures the Earth cables on the right rear
side of the printer, and remove the Earth cables.
3.
Disconnect the ASF Motor connector from the Relay connector.
4.
Disconnect the Relay connector cable from the ASF Assy.
ASF Assy
ASF Motor
5) C.B.S. M3x8
(8±1 kgf.cm)
Figure 4-82. Releasing the Cables (1)
Secure the two Earth cables together with the screw.
Referring to
Figure
cable.
Revision C
Relay
connector
Relay
connector
cable
Earth cables
4-82, correctly route the Relay connector