Electrical - Epson AcuLaser C2600 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C2600:
Table of Contents

Advertisement

EPSON AcuLaser C2600/2600

4.5.10 Electrical

4.5.10.1 NETWORK BOARD, SE-NIC-B82/
GROUNDING PLATE, TYPE-B
NETWORK BOARD, SE-NIC-B82
1.
Remove the COVER HOUSING, CONTROLLER, UNIT.
2.
Remove the 2 screws that secure the NETWORK BOARD, SE-NIC-B82, and
disconnect the NETWORK BOARD, SE-NIC-B82 from CN407 connector on the
BOARD ASSY., MAIN C585 MAIN.
C.P.SCREW,3x6,F/Ni: 2
1.
When securing the NETWORK BOARD, SE-NIC-B82 with
screws, make sure to insert the NETWORK BOARD, SE-NIC-
B82 vertically into the BOARD ASSY., MAIN C585 MAIN.
2.
Confirm that the NETWORK BOARD, SE-NIC-B82 is securely
connected to the board.
GROUNDING PLATE, TYPE-B
1). Remove the COVER HOUSING, CONTROLLER, UNIT.
2). Remove the 2 screws that secure the COVER, TYPE-B to remove the COVER,
TYPE-B.
C.P.SCREW,3x6,F/Ni: 2
3). Release the 2 tabs of the GROUNDING PLATE, TYPE-B that secure the
BRACKET ASSY., I/F, and remove the GROUNDING PLATE, TYPE-B.
1). Insert the central tab of the GROUNDING PLATE, TYPE-B to
the notch of the BRACKET ASSY., I/F.
Disassembly and Assembly
NETWORK BOARD,
SE-NIC-B82
(p.247)
GROUNDING PLATE,
TYPE-B
(p.247)
Disassembling/Assembling the Main Unit
2-2
3)
3)
3)
Reassembly
1)
Reassembly
Figure 4-98. Removal of NETWORK BOARD, SE-NIC-B82/
GROUNDING PLATE, TYPE-B/
Revision B
2-1
2-1
2)-1
2)-1
1
04008101
307