Mp Tray - Epson AcuLaser C2600 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C2600:
Table of Contents

Advertisement

EPSON AcuLaser C2600/2600

4.5.11 MP Tray

4.5.11.1 Pick Up Sensor (DETECTOR, HP; E)/LEVER, PE; B
Pick Up Sensor (DETECTOR, HP; E)
1.
Open the MP TRAY.
2.
Remove the screw that secures the COVER, PICK UP, MP to remove the
COVER, PICK UP, MP.
3.
C.P.POLYWAVEA,3x6,F/Zn: 1
4.
Lift the LEVER, PE; B to move the LEVER, PE, SUB out of the slit of the Pick up
sensor, and remove the Pick up sensor releasing the 3 tabs.
5.
Disconnect the connector from the Pick up sensor.
LEVER, PE; B
1). Remove the COVER, PICK UP, MP.
2). Remove the LEVER, PE; B from the 2 roller bearings of the MP Tray.
Pick up the LEVER, PE; SUB, insert the LEVER, PE; B to the
notch of the MP TRAY, and attach the LEVER, PE; B.
Disassembly and Assembly
(p.323)
Disassembling/Assembling the Main Unit
4-3
4-3
4-3
2-1
Reassembly
Figure 4-114. Removal of Pick Up Sensor/LEVER, PE; B
Revision B
4-2
LEVER,
PE, SUB
4-1
5
4-4
LEVER,
2)
PE; B
04009601
323