EPSON AcuLaser C2600/2600
4.5.3.6 ROLLER, GATE
1.
Remove the CLUTCH, GATE.
(p.259)
2.
Remove the 2ND TRANSFER Assy., ASP.
When handling the ROLLER, GATE, beware of the following
C A U T I O N
instructions.
Extra caution is required not to touch the surface of the
ROLLER, GATE with bare hands, or paper feeding trouble
may occur due to oil of the hand left on the roller.
Do not scratch or contaminate the surface of the ROLLER
GATE.
3.
Remove the 2 E-RING, 7, L/NAs from both ends of the ROLLER, GATE, and
slide the 2 BEARING, 688ZNRs toward the inside of the ROLLER, GATE.
4.
Slide the ROLLER GATE toward rear to draw out the front end of the shaft along
the groove of the frame, and pull the rear end of the shaft out of the shaft hole to
remove the ROLLER GATE.
Insert the chipped end of the ROLLER, GATE to the rear shaft
hole.
5.
Draw out the 2 BEARING, 688ZZNRs from both ends of the ROLLER, GATE.