Epson AcuLaser C2600 Service Manual page 190

A4 full color laser printer
Hide thumbs Also See for AcuLaser C2600:
Table of Contents

Advertisement

EPSON AcuLaser C2600/2600
TROUBLESHOOTING FOR COMPLETE BLANK PAGE 3
No.
Transfer cleaner contact/noncontact control failure
1
2
2ND TRANSFER Assy., ASP installation failure
2nd Transfer Roller contact/noncontact control failure
3
2nd transfer bias charging failure
4
Some areas of a toner image clings to the Fuser Unit (toner offset)
5
Troubleshooting
Cause
Printing-quality troubleshooting (PQT)
Check Point
Power the printer off and back on again.
Perform Timing Adjustment.
Replace the cleaner clutch.
Replace the TRANSFER UNIT, Assy., ASP.
Install the 2ND TRANSFER Assy., ASP correctly.
Power the printer off and back on again.
Perform Timing Adjustment.
Replace the 2nd Transfer Clutch.
Check the connection status between the HVPS and the 2ND
TRANSFER Assy., ASP.
HVPS ↔ [Harness, HV, 2nd Transfer] ↔ 2ND TRANSFER Assy.,
ASP
Replace the 2nd Transfer Roller.
Replace the HVPS.
Check if the voltage supplied from the AC power supply is normal.
Replace the Fuser Unit.
Revision B
Defect Parts
CLUTCH,CLEANER
TRANSFER UNIT, Assy., ASP
---
CLUTCH, 2ND TRANSFER
HARNESS, HV, 2ND TRANSFER
ROLLER, 2ND
HIGH VOLTAGE POWER
SUPPLY, EUKMBE925HA
Fuser unit
190