EPSON AcuLaser C2600/2600
10. Remove the RETAINING RING, 4 that secures the MOUNTING PLATE,
CLUTCH.
11. Remove the three screws that secure the MOUNTING PLATE, CLUTCH and
remove the MOUNTING PLATE, CLUTCH.
C.P.POLYWAVEA,3x6,F/Zn: 3
Pay attention not to lose the SPACER, CLUTCH as it may come off
C A U T I O N
along with the CLUTCH, CLEANER when performing the
following work.
3.
Match the antirotation tab of the MOUNTING PLATE, CLUTCH
with the antirotation groove of the CLUTCH, CLEANER.
4.
Match the 2 positioning holes of the MOUNTING PLATE,
CLUTCH with the dowels.
12. Tilt the CLUTCH, CLEANER upward, release it from the connector of the
STEPPING MOTOR ASSY., DV, and remove the CLUTCH, CLEANER from
the SHAFT, CAM, CLEANER.
5.
Insert the CLUTCH, CLEANER to the SHAFT, CAM,
CLEANER with attention to their shape of cross-section.
A D J U S T M E N T
Be sure to refer to
"5.1.3 Adjustment Execution Timing" (p.366)
R E Q U I R E D
and perform specified adjustments after replacing CLUTCH,
CLEANER.
Disassembly and Assembly
Caution
STEPPING MOTOR
ASSY., DV
Reassembly
Disassembling/Assembling the Main Unit
SPACER,
CLUTCH
12
4
3
4
Figure 4-73. Removal of CLUTCH, CLEANER 3
Revision B
CLUTCH,
CLEANER
MOUNTING
PLATE, CLUTCH
11
10
11
11
Reassembly
5
04005602