EPSON AcuLaser C2600/2600
4.5.2.11 Right Cover Open Sensor (DETECTOR,V-162-3A5)/
Front Cover Open Sensor (DETECTOR,V-162-3A5)
Right Cover Open Sensor
1.
Remove the COVER, INNER.
(p.248)
2.
Remove the screw that secures the Right cover open sensor to remove the Right
cover open sensor.
C.C.P-TITE SCREW,3x14,F/Zn: 1
1.
Match the positioning hole of the Right cover open sensor with the
dowel.
3.
Disconnect the 2 connectors from the Right cover open sensor.
Front Cover Open Sensor
1). Remove the COVER, INNER.
(p.248)
2). Remove the screw that secures the steel plate, which fixes the sensor, to dismount
the steel plate.
C.P.POLYWAVEA,3x6,F/Zn: 1
1). Match the positioning holes of the steel plate that fixes the sensor
with the dowels.
3). Remove the screw that secures the Front cover open sensor to remove the Front
cover open sensor.
C.C.P-TITE SCREW,3x14,F/Zn: 1
2). Match the positioning hole of the Front cover open sensor with the
dowel.
4). Disconnect the 2 connectors from the Front cover open sensor.
Disassembly and Assembly
3)-1
Figure 4-40. Removal of Right Cover Open Sensor/Front Cover Open Sensor
Disassembling/Assembling the Main Unit
2)-1
4)
4)
Front Cover
Open Sensor
Reassembly
1)
Reassembly
2)
Revision B
Reassembly
1
3
Right Cover
3
Open Sensor
2-1
04002801
249