Check item
(10-1-3) Sensor check
Up/Down sensor
Check if shape and movement of the sensor
lever (unified
levers have any abnormality or not.
structure with the
left link lever)
Up/Down sensor
Confirm that the sensor signals are normally
detected by using the SWITCH SCAN function
of the self-diagnostic mode.
Check if the SCAN state changes or not when
the incoming light is interrupted/passed by using
a piece of paper or the like for the transparent
type sensor.

(10-2) Error occurs during the Down movement of the ID unit

Check item
(10-2-1) Check the mechanical load during the Down movement
Mechanical load
Check if abnormal heavy load is applied when
during installation
removing the ID unit.
and removal of the
ID unit
Greasing to the right
Check if the slant surface of the link lever is
and left Up/Down
coated by grease or not.
link levers
Assembled
Check if any part exists or not in the vicinity of
condition of the right
link lever, that hampers movement of the link
and left Up/Down
lever.
link levers
44346001TH Rev.1
Check operation
Actions for NG
results
Replace the left
link lever.
Replace the high
voltage board.
Check operation
Actions for NG
results
Replace the ID
unit, or replace
the right/left side
plate.
Apply grease.
Assemble them
correctly.

7.5.2. (11) Fuser unit error (error 170 to 177)

(11-1) Error occurs immediately after the power is turned on.

Check item
(11-1-1) Thermistor is defective
Note)
Upper thermistor,
Check the respective thermistors if they are
lower thermistor,
shorted or opened internally.
frame thermistor
Check the resistance value at the connector pins
in the bottom of the fuser unit.
(Refer to section 8.1 Resistance check (fuser
unit).)
Installed condition
Check if the fuser nit is pressed in until the
of fuser unit.
connector in the bottom of the fuser unit is surely
connected.
Note! Service calls 171 error and 171 error can occur when the printer temperature
is below 0 . Turn on the power again after the printer temperature has
increased.

(11-2) Error occurs approx. 1 minute after the power is turned on.

Check item
(11-2-1) Temperature increase of fuser unit
Thermostat,
Heater of the fuser unit is controlled of its
halogen lamp
temperature. Check if the fuser unit gets hot or
not by touching it with hands.
If the fuser unit temperature does not increase
and remains cold, check that the resistance
between pin-1 and pin-2, and that in between
pin-3 and pin-4 of the two connectors is in the
range of several ohms to several ten ohms
respectively. (Refer to section 8.1 Resistance
value (fuser unit).)
7. TROUBLESHOOTING
Check operation
Actions for NG
results
Replace the
fuser unit.
If any attempt
of using new
fuser unit as
a trial is going
to be made,
be sure to use
the System
Maintenance
Menu FUSE
KEEP MODE.
Re-set the fuser
unit.
Check operation
Actions for NG
results
Replace the
fuser unit.
If any attempt
of using new
fuser unit as
a trial is going
to be made,
be sure to use
the System
Maintenance
Menu FUSE
KEEP MODE.