Startup Time Of Printer Is Long - Oki C310dn Maintenance Manual

Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Check item
(2-2-2) Motor step losing check (consumable load problem)
Operating conditions
Check if operations of the respective motors are
of the respective
normal or not by using the self-diagnostic mode.
motors
Check if any load exists or not.
"Buzzer" sound when an error occurs.
(2-2-3) Gear tooth disengagement check (consumable load problem)
Operating conditions
Check if operations of the respective motors are
of the respective
normal or not by using the self-diagnostic mode.
motors
Check if any load exists or not.
"Buzz buzz" sound is generated when an error
occurs.
Installation condition
Check by visual inspection if the respective
of each consumable
consumable items are installed in their normal
item
positions in which gears of the consumable
items engage accurately or not.
(2-2-4) Cord routing check
Check the
Remove the CU and PU board, and inspect the
installation
installation conditions of the partition plate by
conditions of the
visual inspection.
partition plate under
the CU and PU
boards.
44346001TH Rev.1
Check operation
Actions for NG
results
Replace the
corresponding
consumable
item.
If any attempt
of using new
part as a trial
is going to
be made, be
sure to use
the System
Maintenance
Menu FUSE
KEEP MODE.
Replace the
corresponding
consumable
item.
If any attempt
of using new
part as a trial
is going to
be made, be
sure to use
the System
Maintenance
Menu FUSE
KEEP MODE.
Replace an
appropriate
mechanical part
as required, or
adjust or repair
If they are not
hooked on the
normal specified
positions,
correct them.
(2-3) Bad odor is generated
Check item
(2-3-1) Bad odor locating
Fuser unit
Remove the fuser unit and check the odor.
Low voltage power
Remove the low voltage power supply unit and
supply unit
check the odor.
(2-3-2) Fuser unit check
Life count of fuser
Check the life count of the fuser unit by using
unit
the self-diagnostic mode.
Check that no
Check that no foreign materials such as paper
foreign material
are stuck inside of the fuser unit.
exists in fuser unit.

(2-4) Startup time of printer is long

Check item
(2-4-1) Fuser unit check
Check that 100V is shown on the label on the
Halogen lamp
rear of the fuser unit.
(2-4-2) Option part check (note)
Extension memory
Reinstall the option part (the extension
memory) and check operation.
SD memory card
Reinstall the option part (the SD memory
card) and check operation.
Note! When the printer has a problem, for example it does not start properly, remove
any CU options (RAM and SD memory card) and check for changes.
7. TROUBLESHOOTING
Check operation
Actions for NG
results
Implement
section (2-3-2).
Replace the low
voltage power
supply unit
The fuser close
to the new fuser
unit smells
some odors.
Remove the
foreign material.
Check operation
Actions for NG
results
Replace the
fuser unit.
Replace the
option part.
Replace the
option part.