Oki Data CONFIDENTIAL
4.2.12 Operator panel assembly
(1) Remove the right side cover and plate shield assembly.
(2) Remove the cable of the operator panel assembly.
* CU/PU PCB OPWE connector
(3) Remove the two screws ① to detach the operator panel assembly ② .
44346001TH Rev.1
4.2.13 Board IBB and LCD
(1) Remove the operator panel assembly.
(2) Unlatch the three portions A.
(3) Detach the Board IBB ① .
(4) Unlatch the two portions B.
(5) Detach the LCD assembly ② .
4.REPLACEMENT OF PARTS
67 /