Oki C310dn Maintenance Manual page 103

Table of Contents

Advertisement

Oki Data CONFIDENTIAL
• The following message appears during printing:
P=***
W=***
P: Number of test print pages
W: Wait time
• The displays are switched by pressing
T=*** U=***[###]
H=***%L=***[###]
U: Three asterisks (***) identifies a measured upper heater temperature (in
Celsius). Three sharp signs in square brackets ([###]) identifies a target
print temperature (in Celsius).
L: Three asterisks (***) identifies a measured lower heater temperature (in
Celsius). Three sharp signs in square brackets ([###]) identifies a read
lower thermistor AD value (in hex).
T: A measured ambient temperature (in Celsius).
H: A measured ambient humidity (in percent figures).
• The displays are switched by pressing
KTR=*.** YTR=*.**
MTR=*.** CTR=*.**
YTR, MTR, CTR and KTR indicate the set transfer voltage values for colors,
respectively (in kV).
• The displays are switched by pressing
KR=*.** YR=*.**
MR=*.** CR=*.**
KR: A black transfer roller resistance value (in uA).
YR: A yellow transfer roller resistance value (in uA).
MR: A magenta transfer roller resistance value (in uA).
CR: A cyan transfer roller resistance value (in uA).
44346001TH Rev.1
.
.
.
• The displays are switched by pressing
ETMP=***UTMP=***
REG=****EXT=***
ETMP: A parameter for correction of constant hopping motor speed (an
ambient temperature) (in decimal).
UTMP: A parameter for correction of constant fuser motor speed (a target
fusing temperature) (in decimal).
REG: A hopping motor constant-speed timer value (a set input/output value)
(in hex).
EXT: A fuser motor constant-speed timer value (a set input/output value) (in
hex).
• The displays are switched to the following by pressing
ID=****
ID: An image drum motor constant-speed timer value (a set input/output
value) (in hex).
• The displays are switched pressing
BELT=****
FRM [***] ( xxx )
BELT: A belt motor constant-speed timer value (a set input/output value) (in
hex).
FRM: Three asterisks in square brackets ([***]) identifies a read frame
thermistor AD value (in hex).
Three cross signs in brackets ((xxx)) identifies a frame temperature (in
Celsius).
• The displays are switched by pressing
DB:k**y**m**c**
DB: A developing voltage setting table identification number (in hex).
5. MAINTENANCE MENUS
.
.
.
.