Oki C310dn Maintenance Manual page 95

Table of Contents

Advertisement

Oki Data CONFIDENTIAL
(1) Menu option switching
LEVEL1
or
is used to select the option shown in a shaded area ( XXXXX ), and pressing OK executes the option. OK or
( XXXXX ), and, after that,
[
]
[
]
SWITCH
MOTOR &
TEST PRINT
SCAN
CLUTCH
PRINT
[
]
EXECUTE
PAPER ROUTE :
TEST
[
]
PU
TEST
ID MOTOR
PATTERN
TONER SENS
BELT MOTOR
TEST
CVO UP_LU_FU
FUSER MOTOR
CASSETTE
REG L/
REGIST MOTOR
*1
R_OHP_WG
T1 HOPPING
PAGE
HT
MOTOR
COLOR
THERMISTER
FRONT MOTOR
DUPLEX
HUM_TEMP
REGIST
_DEN
SHUTTER
*1: TRAY2 is displayed
BELT_T
DUPLEX
ID UP/DOWN
MOTOR
TAG COLOR
DUPLEX
DISTONER
CLUTCH
FULL_BOX
T2 HOPPING
T1 PE_PNE_
MOTOR
CVO_CA
T2 FEED
T1 HOP_LIFT
CLUTCH
T2 PE_PNE_
ID UP/DOWN
CVO_CA
LV FAN TEST
T2
ID FAN TEST
HOP_LF_FED
FRONT FAN
DUP RA_FNT
TEST
Note:
Note:
Refer to a Switch Scan
A motor is kept running by
test sheet.
holding down the OK button
(for two seconds) to determine
the motor.
44346001TH Rev.1
or
is used to select an option. A selected test is executed by pressing OK, and ended by pressing
[
]
[
]
[
]
[
]
REG ADJUST
DENS ADJ
TEST
TEST
[
]
[
]
REG ADJ
DENS ADJ
EXECUTE
EXECUTE
REG ADJ RESULT
DENS ADJ PAR-
*2
SET
BLT REFLECT TEST
DENS ADJ
RESULT *3
BLT REFLECT
RESULT
AUTO
CALIBRATION
AUTO CALIB
BLACK
only when the printer
Density adjustment test result
has the tray 2 in it.
display items below option marked
with *3:
DENS ADJ RESULT
LEV0 V/D OUT YMC
Color registration adjustment test result
LEV0 V/D OUT K
display items below option marked with
LEV0 V/D OUT RD
*2:
LEV0 V/D OUT YMC
REG ADJ RSLT
LEV0 V/D OUT K
SNS CARIBRAT (L)
FINE ADJ Y [Y-L]
H_DUTY DENS-K
SNS CARIBRAT (R)
FINE ADJ Y [Y-L]
H_DUTY DENS-Y
D-RANGE (L) Y,M,C
FINE ADJ Y [Y-R]
H_DUTY DENS-M
D-RANGE (R) Y,M,C
FINE ADJ Y [Y-R]
H_DUTY DENS-C
CRSE ADJ Y L,R,X
FINE ADJ Y [X-L]
L_DUTY DENS-K
CRSE ADJ M L,R,X
FINE ADJ Y [X-R]
L_DUTY DENS-Y
CRSE ADJ C L,R,X
FINE ADJ M [Y-L]
L_DUTY DENS-M
FINE ADJ Y L,R,X
FINE ADJ M [Y-L]
L_DUTY DENS-C
FINE ADJ M L,R,X
FINE ADJ M [Y-R]
FINAL DENS-K
FINE ADJ C L,R,X
FINE ADJ M [Y-R]
FINAL DENS-Y
REG ADJ Y L,R,X
FINE ADJ M [X-L]
FINAL DENS-M
REG ADJ M L,R,X
FINE ADJ M [X-R]
FINAL DENS-C
REG ADJ C L,R,X
FINE ADJ C [Y-L]
DB DENS VALUE
CRSE ADJ Y [Y-L]
FINE ADJ C [Y-L]
DELTA-K 01=#***
CRSE ADJ Y [Y-R]
FINE ADJ C [Y-R]
DELTA-K 04=#***
CRSE ADJ Y [X]
FINE ADJ C [Y-R]
DELTA-K 07=#***
CRSE ADJ M [Y-L]
FINE ADJ C [X-L]
DELTA-Y 01=#***
CRSE ADJ M [Y-R]
FINE ADJ C [X-R]
DELTA-Y 04=#***
CRSE ADJ M [X]
DELTA-Y 07=#***
CRSE ADJ C [Y-L]
DELTA-M 01=#***
CRSE ADJ C [Y-R]
DELTA-M 04=#***
CRSE ADJ C [X]
DELTA-M 07=#***
DELTA-C 01=#***
DELTA-C 04=#***
DELTA-C 07=#***
DENS-K ▲▲▲
ENGINE DIAG LEVEL1
[
]
[
]
CONSUMABLE
PRINTER STATUS
STATUS
K-IMPRESSIONS
[
]
[
]
K-ID UNIT
Y-IMPRESSIONS
M-IMPRESSIONS
Y-ID UNIT
M-ID UNIT
C-IMPRESSIONS
C-ID UNIT
TOTAL SHEETS CNT
FUSER UNIT
TR BELT UNIT
K-TONER (FULL)
Y-TONER (FULL)
M-TONER (FULL)
Options below FACTORY MODE SET option *5
C-TONER (FULL)
K-STC MODE CNT
FACTORY MODE
Y-STC MODE CNT
FACTORY MODE
M-STC MODE CNT
SHIPPING MODE
C-STC MODE CNT
Note: A parameter determination is made by holding
K OVER RIDE CNT
down the OK button (for three seconds) (NBC).
Y OVER RIDE CNT
M OVER RIDE CNT
C OVER RIDE CNT
Options below FUSE INTACT option *6
FUSE INTACT
Note:
BELT UNIT
A parameter reset is
performed by holding
FUSE UNIT
down the OK button (for 10
seconds) (NBC).
ID UNIT
DENS-Y▲▲▲▲
DENS-M▲▲▲▲
DENS-C▲▲▲▲
BEF COL STD=***H
AFT COL STD=***H
BEF BLK STD=***H
AFT BLK STD=***H
is used to switch to the option in a non-shaded area
.
[
]
[
]
[
]
[
]
[
]
FACTORY
SENSOR
MODE SET
SETTING
[
]
[
]
[
]
FACTORY MODE
TONER
SENSOR
*5
BELT UNIT
FUSE INTACT
CHECK
*6
ID UNIT
CHECK
UP/DOWN
SENSOR
REG ADJ
ERROR
DRUM OVER
LIFE
A factory working mode.
WR POINT
Deselects a factory working mode.
REV
BOTTOM
WRT POINT
Note:
A parameter determination
is made by holding down the
OK button (for three seconds)
(NBC).
INTACT: Has not be blown./BLOWN:
Already blown.
INTACT: Has not be blown./BLOWN:
Already blown.
INTACT: Has not be blown./BLOWN:
Already blown.
5. MAINTENANCE MENUS
[
]
LED HEAD
NVRAM
DATA
PARAMETER
[
]
K
CLEAR
Y
M
C
LED head serial
number display
n 01 23 45 6789
1234567890123
n: K, Y, M, C
95 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C330dnC510dnC530dnC330C530

Table of Contents