Mounting the burner

10 Mounting the burner
This chapter explains how to install the burner.
NOTICE: Damage to boiler due to incorrect
burner.
B Only use burners that conform to the
technical requirements of the boiler (see
Chapter 3, page 11).
B Close the burner door and secure with 4 machine
screws (M16 × 140) in the positions shown. Tighten
the machine screws evenly crosswise.
You can obtain undrilled or predrilled burner
plates (hole pattern depends on burner) as
accessories from Buderus.
If you have ordered an undrilled burner plate, you will have
to machine this on site:
B Drill or cut the burner plate (
the required burner tube diameter Ø 10 5/8 inches
(270 mm).
B Drill burner attachment holes using the burner flange as
a template.
B Screw burner plate onto the burner door (seal with GP
sealant rope; diameter Ø 25/64 inches (10 mm)).
B Screw the burner to the burner plate.
B Cut insulating rings to match the burner tube diameter
(
Fig. 56, [2]).
B Fill the remaining gap between the burner door thermal
insulation and the burner tube
appropriate insulating rings or boiler packing insulation
(
Fig. 56, [3]).
B Connect the vent blower connection to the burner to
ensure the inspection window remains free of deposits.
42
Fig. 56, [1]) to match
Fig. 56, [4]) using the
1
Fig. 56 Mounting the burner
Logano G615 - Subject to technical modifications
2
3
4
6 720 642 623-63.1o