Mounting The Burner; Connecting The Fuel Supply - Buderus Logano G115 WS US/CA Installation And Service Instructions Manual

Low-temperature oil boiler
Hide thumbs Also See for Logano G115 WS US/CA:
Table of Contents

Advertisement

5.4

Mounting the burner

Only burners that comply with the boiler specification can
be used with this boiler. (
Caution: Risk of system damage from use of
incorrect fuel.
V Only use burners which meet the techni-
cal boiler requirements.
V Screw studs included with the B-Kit to the burner door.
Approved burners with accessories (such as
aquastat and circulator) are also available as
a package from Buderus.
V Install burner with the correct nozzle and settings (air,
pump pressure, turbulator settings, flange position).
V Place the seal on the studs and secure the burner with
the included nuts.
For details of the correct burner settings
flue system documentation and
burner documentation.
V Follow the manufacturer's direction for installation, fine
adjustment and regular maintenance procedures.
5.5

Connecting the fuel supply

Make the fuel connection in accordance with all applica-
ble local and national codes and regulations. We recom-
mend fitting a fuel filter and de-aerator.
V Visually inspect the fuel pipe and clean or replace, if
necessary.
V Install a shut-off valve into the fuel supply pipe.
V Connect the fuel pipe free of stress to the boiler.
V Check the fuel line for leaks.
Logano G115 WS US/CA - Technical specifications are subject to change without prior notice.
Chapter 2.7, page 8).
Fig. 18 Burner door mounting holes
Installing the boiler
7 747 019 141-18.1RS
5
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logano g115/3 wsLogano g115/4 wsLogano g115/5 ws

Table of Contents