7
Boiler block assembly
1
2
3
Fig. 32 Insert the flue gas baffles (boiler block with
13 sections)
1
Flue gas baffles with sickle profile (sectional baffle)
2
Flue gas baffles with sickle profile (sectional baffle)
3
Flue gas baffle with wave profile
Number of sections
9
10
11
12
13
14
15
16
Tab. 11 Number of flue gas baffles
7.10 Installation of the boiler jacket
7.10.1 Fitting the thermal insulation
The thermal insulation provided corresponds to the boiler
size.
B Arrange the thermal insulation on the boiler block as
shown in the diagram in
left of the boiler blocks represent the number of boiler
sections).
B Push thermal insulation under the boiler block. The
boiler feet are placed in the cut-outs in the thermal
insulation.
30
6 720 642 625-29.1o
top left
2 × sickle profile
2 × sickle profile
2 × sickle profile
2 × sickle profile
2 × sickle profile
2 × sickle profile
1 × wave profile
1 × wave profile
2 × sickle profile
2 × sickle profile
1 × wave profile
1 × wave profile
–
–
Fig. 35 (the figures to the
Fig. 33 Insert the flue gas baffles (boiler block with
15 sections)
1
Flue gas baffle with wave profile
Number of flue gas baffles
top right
bottom left
2 × sickle profile
2 × sickle profile
2 × sickle profile
2 × sickle profile
1 × wave profile
1 × wave profile
–
1 × wave profile
–
Fig. 34 Boiler block with thermal insulation
1
Thermal insulation
Logano G615 - Subject to technical modifications
720 42 25-30.1o
bottom right
2 × sickle profile
2 × sickle profile
2 × sickle profile
2 × sickle profile
1 × wave profile
1 × wave profile
1 × wave profile
–
–
6 720 642 625-3 . o