15. Reattach the cover to the console.
A. Using a Phillips screwdriver, reattach the four
screws securing the rear console cover to the
front console cover. See Figure 12.
16. Attach the RJ-45 and audio cables to the
signal isolator.
A. Attach the RJ-45 (C) and audio cables (B)
to the signal isolator (Q). See Figure 17.
(Q)
Figure 17
B. Insert the RJ-45 (C) cable down through
the lower rear console cover opening.
See Figure 17.
17. Attach the signal isolator.
A. Attach signal isolator (Q) cable to the PC
board. See Figure 17.
B. Peel off backing from tape and attach the
signal isolator (Q) to the mounting plate.
See Figure 17.
18. Reattach the battery door cover to the
console.
A. Using a Phillips screwdriver, reattach the
one screw securing the console battery
door cover to the console cover. See
Figure 12.
19. Install cables in console mount.
A. Locate the console mount (A).
B. Locate the console, heart rate, coax and
power cables on the mainframe assembly.
C. Insert the cables into the bottom of the
console mount (A) until the cable exit the
top. See Figure 18.
Lockwasher
Mounting
Plate
(C)
(B)
Figure 18
20. Attach the console mount.
21. Insert the coax, power and RJ-45 cables.
NOTE: Exactly 8" (20 cm) of cable must exit the top of
22. Attach the display console.
Coax
RJ-45
Power
Cable
Cable
Cable
8"
(20 cm)
Monitor
Mount
(4)
BHSCS
(4)
(A)
BHSCS
(3)
A. Position the console mount (A) on the main
frame assembly and hand thread each of the
three BHSCS. See Figure 18.
B. Securely fasten the BHSCS with the 7/32" Allen
wrench.
A. Route the coax and power cables up through
the monitor mount until 8" (20 cm) of cable
exit the top. See Figure 18.
the monitor mount.
B. With 8" of coax and power cables exiting
the top of the console assembly, pull the
extra coax and power cables out of the
bottom of the main frame.
C. Insert the RJ-45 cable that is attached to the
display console up through the monitor mount.
See Figure 18.
A. Connect the console and heart rate cables
exiting the top of the console mount to the
console. See Figure 18.
Display
Console
Console
Cables
Heart Rate
Cable
Console, Heart
Rate, Coax and
Power Cables

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents