CYBEX Arc Trainer 425A Service Manual page 39

Cardiovascular systems
Hide thumbs Also See for Arc Trainer 425A:
Table of Contents

Advertisement

Kit No. 425AK004 - Right Front Leg
425AK005 - Left Front Leg
NOTE: This instruction sheet describes how to
replace the front legs in the Arc Trainer 425A.
Tools Required
• Phillips screwdriver
• 3/4" Open end wrench
• 5/32" Allen wrench
• 7/32" Allen wrench
• Grease
1. Read and understand all instructions
thoroughly before installing this kit.
2. Verify you received the appropriate kit.
See Figure 1.
A
A. Right front leg, (1), 425AK004
B. Left front leg, (1), 425AK005
C. Pastic end cap, (1), 425A-485
D. Spacer, (1), 425A-481
E. Loctite, (3), YA000201
Figure 1
3. Disconnect the external power source.
A. Unplug the power cord from the power outlet.
! WARNING: Disconnect the power cord before
continuing this procedure. Keep wet
items away from inside parts of the
unit. Electrical shock could occur
even if the unit is unplugged.
®
Arc Trainer
B
C
D
E
425A Front Leg
4. Remove the front cover.
A. Using a Phillips screwdriver, remove the
four screws securing the front cover. See
Figure 2.
Front
Cover
Screws
(4)
Figure 2
B. Remove front cover.
5. Remove top cover.
A. Using a Phillips screwdriver, remove the
screw securing the top cover. See Figure 3.
Figure 3
B. Remove top cover.
6. Remove upper side covers.
A. Using a Phillips screwdriver, remove the
screw securing each upper side cover.
See Figure 4 .
Installation Instructions
Screw

Hide quick links: