Kit No. 425AK002
NOTE: This instruction sheet describes how to
replace the Drive Link in the Arc Trainer
425A.
Tools Required
• Phillips screwdriver
• 5/32" Allen wrench
1. Read and understand all instructions thoroughly
before installing this kit.
2. Verify kit contents. See Figure 1.
A
A. Drive Link, (1), 425AK002
B. Loctite, (1), YA000201
Figure 1
3. Disconnect the external power source.
A. Unplug the power cord from the power outlet.
! WARNING: Disconnect the power cord before
continuing this procedure. Keep wet
items away from inside parts of the
unit. Electrical shock could occur
even if the unit is unplugged.
4. Remove the front cover.
A. Using a Phillips
screwdriver, remove
the four screws
securing the front
cover. See Figure 2.
B. Remove front cover.
®
Arc Trainer
• 3/4" Open end wrench
• 5/16" Allen wrench
B
Front
Cover
Screws
(4)
Figure 2
425A Drive Link
5. Remove top cover.
A. Using a Phillips screwdriver, remove the
screw securing the top cover. See Figure 3.
Figure 3
B. Remove top cover.
6. Remove upper side cover.
A. Using a Phillips screwdriver, remove the
screw securing the upper side cover.
See Figure 4.
Locking
Connectors
Upper Left
Side Cover
Figure 4
B. Remove upper side cover.