CYBEX Arc Trainer 425A Service Manual page 43

Cardiovascular systems
Hide thumbs Also See for Arc Trainer 425A:
Table of Contents

Advertisement

Kit No. 425AK006 - Right Input Handle Kit
Kit No. 425AK007 - Left Input Handle Kit
NOTE: This instruction sheet describes how to
replace the input handle in the Arc
Trainer 425A.
Tools Required
• 5/32" Allen wrench
• 7/32" Allen wrench (2)
• Grease
1. Read and understand all instructions
thoroughly before installing this kit.
2. Verify kit contents. See Figure 1.
A
B
A. Right Hand Input Handle, (1), 425AK006
B. Left Hand Input Handle, (1), 425AK007
C. Loctite, (1), YA000201
Figure 1
3. Remove the proper input handle.
A. Unplug the power cord from the power outlet.
B. Confirm you have the proper replacement
handle. NOTE: The two handles are not
interchangeable.
®
Arc Trainer
C
425A Input Handle
C. Using a 5/32" Allen wrench, remove the
BHSCS (Button Head Socket Cap Screw),
end cap and nylon washer securing the
S-link to the input handle. See Figure 2.
BHSCS/
Loctite
E
nd Cap
Figure 2
D. Unplug the heart rate cable. See Figure 3.
E. Using two 7/32" Allen wrenches remove the
BHSCS and washer from the pivot shaft.
See Figure 3.
F. Slide the pivot shaft through main frame
opening to remove input handle. See
Figure 3.
G. Remove the proper input handle.
Left Input Handle
BHSCS/
Loctite
Washer
Heart Rate
Cables
Figure 3
Installation Instructions
Input
Handle
Loctite
Grease
S-Link
Nylon
Washer
Right Input Handle
Opening
Pivot Shaft
Grease
Loctite
Washer
BHSCS/
Loctite