10. Remove the display console.
A. Using a 5/32" Allen wrench, remove the four
BHSCS with lock washers securing the display
console to the console mount. See Figure 8.
Lockwasher
(4)
BHSCS
(4)
Console
Mount
BHSCS
(3)
Figure 8
B. Disconnect the console and heart rate cables
from the display console. See Figure 8.
C. Using a 7/32" Allen wrench, remove the three
BHSCS securing the console mount to the
frame. See Figure 8.
11. Route the coax and power cable.
A. Using a side cutter, cut the three cable ties.
See Figure 9.
Measure out 44" or 47" of cable
(see step 11E)
Cable Tie
Drive frame assembly not shown.
Figure 9
Display
Console
Console and
Heart Rate
Cables
Access
Hole
Coax Cable and
Power Cable with
male connector
NOTE: The Power Cable (B) has a male and female
connector at either end. Make sure the female
end goes to the Monitor and the male end
is at the base. See Figure 10.
Female
Connector
Figure 10
B. Locate the coax and power cable (B).
C. Tape the ends of the coax and power cable
together (making it easier to guide the cables
down the frame).
D. Route the cable inside top of frame as shown
in Figure 9.
E. For monitors with center connectors, measure
out 44" of cable. For monitors with side
connectors, measure out 47" of cable.
F. Pull the extra coax and power cables out of the
bottom of the main frame. See Figure 9.
G. Attach three cable ties (F) replacing the ones
removed in step 11A. See Figure 9.
NOTE: Leave cable ties loose for cable
adjustment. They will be tightened later.
12. Install cables in console mount.
A. Locate the console mount (A).
B. Locate the console, heart rate, coax and
power cables on the mainframe assembly.
C. Insert the cables into the bottom of the console
mount (A) until the cables exit the top of the
console mount opening. See Figure 11.
Male