Monitor
Back Plate
Monitor
Bracket
Mounting
Hardware
:
NOTE
Refer to monitor manufacturer's installation
instructions for cable connection locations
(supplied with the monitor).
Figure 13
B. Remove the tape holding the coax and power
cable ends together and install them in to their
connections on the monitor. NOTE: Refer to
monitor manufacturer's installation instructions
for cable connection locations (supplied with
the monitor).
C. Reinstall the monitor to the monitor back plate
(if removed).
19. Tighten the three cable ties.
A. Pull the loose coax and power cables
through the access hole. See Figure 9.
B. Tighten the three cable ties securely.
See Figure 9.
20. Plug in AC/DC adapter and coax cables.
A. Locate the AC/DC adapter supplied with the
monitor and plug into the coax and power
cable exiting the base of the Arc.
B. Plug the power cord into the AC/DC adapter.
NOTE: You will need a power adapter and a
A/V adapter.
C. Thread the antenna/cable source cable
(supplied at the site location) into the coax
and power cable exiting the base of the Arc.
21. Attach the lower side covers.
A. Hold the lower covers in place. See Figure 7.
B. Using a Phillips screwdriver, tighten the four
screws securing each lower side cover.
22. Attach the upper side covers.
A. Place the upper side covers in position. See
Figure 6.
B. Using a Phillips screwdriver, tighten the
screw securing each upper side cover.
23. Attach the top cover.
A. Place the top cover in position. See Figure 5.
B. Using a Phillips screwdriver, tighten the
screw securing the top cover.
24. Attach the front cover.
A. Place the front cover in position. See Figure 4.
B. Using a Phillips screwdriver, tighten the
four screws securing the front cover.
25. Attach the input handes.
A. Position right input handle vertically and align
handle opening with mainframe opening.
See Figure 3.
B. Insert pivot shaft into mainframe and handle
openings. See Figure 3.
C. Position left input handle vertically and align
handle opening with mainframe opening.
D. Push pivot shaft through opening.
E. Apply loctite (H) to the two BHSCS
(removed in step 5C) and into where
they will be threaded.
F. Using two 7/32" Allen wrenches, attach the
two BHSCS/Loctite and two washers to the
pivot shaft. See Figure 3. NOTE: Handle will
wobble if not securely tightened.
G. Attach the heart rate cables. See Figure 3.