4. Install the proper new input handle.
A. Place grease on the outside of pivot shaft.
See Figure 3.
B. Position the new input handle vertically and
align with the main frame opening. See Figure 3.
C. Push pivot shaft through handle opening and
main frame opening. See Figure 3.
D. Place a drop of loctite (C) on the BHSCS and
another drop inside the pivot shaft where the
BHSCS will be tighten into.
E. Using both 7/32" Allen wrenches, install the
BHSCS/loctite and washer as shown in
Figure 3. NOTE: Handles will wobble if not
securely tightened.
5. Attach S-Link.
A. Place grease on outside of shaft. See Figure 2.
B. Attach the S-link to the new input handle. See
Figure 2.
C. Place a drop of loctite (C) on the BHSCS
(removed in step 3C) and another drop into
the shaft where it will be threaded into.
D. Using 5/32" Allen wrench, secure the S-Link to
the handle using the BHSCS/loctite, end cap
and nylon washer (removed in step 3C). See
Figure 2.
6. Test unit for proper operation.